LT-100 Semi Automated Clinical Chemistry Analyzer


A versatile semi-automated clinical chemistry analyzer offering excellent performance with low maintenance and reagent consumption.
Designed with user-friendly software, flexible testing modes, and fit-and-forget operation for efficient clinical laboratory diagnostics.


Key Features

  • Versatile & Easy to Use – Intuitive operation with minimal training required
  • Excellent Performance – High-precision measurements with 0.0001 Abs resolution
  • Low Maintenance – Minimal upkeep requirements for hassle-free operation
  • Low Reagent Consumption – Cost-effective testing with optimized reagent usage
  • Low Cost Per Test – Economical solution for routine clinical chemistry
  • Minimal Training – Quick learning curve for laboratory staff
  • Fast Flexible Backup – Rapid data backup and retrieval capabilities
  • Fit & Forget – Reliable automated operation with minimal intervention
  • User Friendly Software – Intuitive interface for seamless workflow
  • 50+ Direct Test Keys – Quick test selection for improved efficiency


Testing Capabilities

Method of Calculations


  • Absorbance
  • End Point
  • Fixed Time (with standard or factor)
  • Kinetics
  • Differential/Coagulation - PT/APPT
  • Multipoint up to 10 standards

Test Modes


  • End point method with storage of abs of reagent blank in memory
  • Graphs for KIN test
  • Triplicate calibration mode for EP/KIN/Fix time
  • Triplicate mode of sampling with SD/CV
  • Online graph and OD for kinetic tests
  • Graph editing facility with estimation of result

Sample Types


  • Serum
  • Plasma
  • CSF
  • Urine
  • Whole Blood
  • Hemolysate

Built-in Calculators


  • Lipid profile calculator
  • Globulin ration calculator
  • S. Iron TIBC calculator
  • Bilirubin calculator


Technology Advantages

Optical System


  • Absorption spectrophotometry principle
  • Measurement range: -0.1 to 3.0 absorbance
  • Photometric range: 0-3.0 Abs with 0.0001 Abs resolution
  • Automatic filter wheel for wavelength selection
  • 7 wavelengths: 340, 405, 505, 546, 578, 630 & 670 nm (with option to add one more)
  • Bandwidth: 8nm (±2nm)
  • Halogen lamp 12v/20W or 6v/10w light source
  • Schottkey type photodiode-silicon detector
  • Monochromatic and Bi-chromatic mode

Temperature Control


  • Thermostat flowcell/cuvette chamber
  • Accuracy: ±0.1°C
  • Peltier regulated from 20°C in steps of 1°C

Quality Assurance


  • Utility mode for self-diagnosis checking with 16 bit ADC
  • 3 controls per test (Low, normal & high)
  • Quality control storage
  • Levy-Jennings charts & Westagard's rules

Operational Features


  • Air purge between samples to avoid carryover
  • Lamp saver mode for extended bulb life
  • Print out of laboratory and doctor's name
  • Bi-directional peristaltic pump with programmable sipping volume (50 μL to 1.0ml)


Programming & Data Management

Programming Capacity


  • Table of tests: up to 235
  • Table of units: up to 9 units (editable)
  • Memory: 50000+ test results

Interface & Connectivity


  • Graphic LCD 240/128 pixels screen
  • Tactile soft-touch keyboards with USB option
  • Built-in 57 mm thermal printer
  • RS-232 for PC connection
  • Parallel port for 80 column dot matrix printer


Cuvette System

Flow Cell Specifications


  • Volume: ≤35 μL
  • Temperature programmable for 25°C, 30°C, 37°C

Reagent Handling


  • Reagent Aspiration Volume: 250 μL to 350 μL
  • Cuvettes: Semi-micro plastic or glass


Summary:
A reliable semi-automated clinical chemistry analyzer delivering comprehensive testing capabilities with excellent precision,
low operational costs, and user-friendly operation ideal for small to medium-sized clinical laboratories.

Technical Specifications

General Information


ParameterSpecification
Analyzer TypeSemi Automated Clinical Chemistry Analyzer
ModelLT-100
PrincipleAbsorption spectrophotometry
SoftwareUser friendly software with multiple testing modes


Optical System


ParameterSpecification
PrincipleAbsorption spectrophotometry
Measurement RangeFrom -0.1 to 3.0 absorbance
Photometric Range0-3.0 Abs with resolution of 0.0001 Abs
Spectral RangeAutomatic via filter wheel
Filters340, 405, 505, 546, 578, 630 & 670 nm
(can be added more filter)
Bandwidth8nm (±2nm)
Light SourceHalogen lamp 12v/20W or 6v/10w
ZeroAutomatic
SettingsMonochromatic and Bi-chromatic mode
DetectorSchottkey type photodiode - silicon


Test Methods


ParameterSpecification
MethodsAbsorbance, End Point, Fixed time (with standard or factor), Kinetics, Differential/Coagulation - PT/APPT, Multipoint up to 10 standards
Calibration ModesTriplicate calibration mode for EP/KIN/Fix time
Sampling ModesTriplicate mode of sampling with SD/CV
Test Selection50+ Direct test keys for test selection


Sample Handling


ParameterSpecification
Sample TypeSerum, Plasma, CSF, Urine, Whole blood, Hemolysate
Flow Cell Volume≤35 μL with temperature programmable for 25C, 30C, 37C
Reagent Aspiration Volume250 μL to 350 μL
CuvettesSemi-micro plastic or glass


Temperature Control


ParameterSpecification
SystemThermostat: Flowcell/cuvette chamber
Accuracy±0.1°C
RegulationPeltier regulated from 20°C in steps of 1°C


Interface & Display


ParameterSpecification
ScreenGraphic LCD 240/128 pixels
KeyboardsTactile Soft - Touch/USB*
PrinterBuilt-in 57 mm thermal printer
PC ConnectionRS - 232 for pc connection
Parallel PortFor 80 column dot matrix printer*
Suction SystemBi-Directional peristaltic pump/Sipping volume programmable from 50 uL to 1.0ml


Programming & Storage


ParameterSpecification
Table of TestsUp to 235
Table of UnitsUp to 9 units (editable)
Memory50000+ test results


Quality Control


ParameterSpecification
Controls3 controls per test - Low, normal & high
QC StorageQuality control storage
QC ChartsLevy-Jennings charts & Westagard's rules
Self-DiagnosisUtility mode for self diagnosis checking/16 bit ADC


Built-in Calculators


FeatureAvailable Calculations
CalculatorsLipid profile, Globulin ration, S. Iron TIBC, Bilirubin


Physical Specifications


ParameterSpecification
Dimensions13mm diameter


Electrical Specifications


ParameterSpecification
Voltage110-220 V/50-60 Hz
Power Supply<110W


Environmental Requirements


ParameterSpecification
Temperature10°C to 40°C
Relative Humidity<80%


Additional Features


FeatureDescription
Kinetic TestOnline graph and OD, Graph editing facility, estimation of result
Air PurgeBetween sample to avoid carry over/lamp saver made
Print OutLaboratory and doctor's name
StorageEnd point method - Storage of abs of regent blank in memory/graphs for KIN test