A state-of-the-art fully automated chemistry analyzer designed for precision, efficiency, and ease of use.
Engineered to handle multiple testing requirements with high accuracy and intelligent automation, delivering reliable results for a wide menu of assays.
Summary:
A next-generation fully automated clinical chemistry analyzer built for accuracy, reliability, and intelligent automation.
Combining precise sampling, efficient reaction management, and robust data handling to deliver dependable laboratory performance with minimal operator intervention.
| Parameter | Specification |
|---|---|
| Machine Type | Random access, open reagent & locked reagent (optional) |
| Test Speed | Constant 200 tests/hour (Mono or Double reagent) |
| Test Principle | Colorimetric method, turbidimetry |
| Test Methods | 1-point end, 2-point end, Fixed-Time, Kinetics |
| Calibration Type | Linear & Nonlinear |
| Parameter | Specification |
|---|---|
| Sample Tray | 40 sample positions |
| Sample Tube | Micro cup, test tube & blood collection tube can be used (Ø12-13mm × 25-100mm) |
| Sample Volume | 2-30 µl, step by 0.1 µl |
| Sample Probe | Liquid surface detection, timely tracking for liquid volume Collision avoidance |
| Sample Barcode | Sample barcode reader (optional) |
| Parameter | Specification |
|---|---|
| Reagent Tray | 80 reagent positions (40 for R1 & 40 for R2) Non-stop cooling system with peltier pad inside 24 hours 2°C-14°C Open system, could accept any reagent |
| Reagent Volume | 20-300µl, step by 1µl |
| Reagent Needle | Liquid surface detection, timely tracking for liquid volume Collision avoidance |
| Reagent Barcode | Reagent barcode reader (optional) |
| Parameter | Specification |
|---|---|
| Reaction Tray | 44 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance |
| Reaction Volume | 150µl-330µl |
| Reaction Time | 10 minutes |
| Temperature | Peltier pad incubation system Reaction temperature (37°C ± 0.1°C) |
| Parameter | Specification |
|---|---|
| Onboard Laundry | Multi-stage on board laundry system, automatic cleaning and drying of cuvettes |
| Parameter | Specification |
|---|---|
| Mixer | Paddle-type mixing, effective reducing of carry-over |
| Parameter | Specification |
|---|---|
| Light Source | Halogen lamp |
| Wavelength | 340nm, 405nm, 450nm, 505nm, 546nm, 578nm, 630nm, 700nm (4 more options) |
| Absorbance Range | 0-4.0 Abs |
| Resolution | 0.0001 Abs |
| Parameter | Specification |
|---|---|
| Operating System | Windows XP, Windows 7, Windows 8, Windows 10 |
| Data Processing | • Automatic calibration • Test combination • Effective time management of reagents • Serum index • Whole process detection • Linear expansion of enzyme • Blank deduction • Cuvette memory • Cross infection prevention • Patient information memory and association input • Automatic report audit • Data fuzzy query • Report statistics and printing • Reference range grading • Alarm information classification • User operation privilege classification management |
| Report Printing | 6 formats optional, support custom pattern |
| Interface | TCP/IP network interface |
| Parameter | Specification |
|---|---|
| Dimensions | 745mm × 540mm × 530mm (L × W × H) |
| Weight | 45.4 kg |
| Parameter | Specification |
|---|---|
| Power Supply | AC 110/220V ± 10%, 50/60 Hz, 650W |
| Water Consumption | 8 L/hour (maximum) |
Note: Since R&D is a continuous process, specifications, features, and aesthetics are subject to change without prior notice or obligation.
Download or view the detailed brochure for Analytica 200